  • Temperature Control System Solution Provider - Shanghai Yuexi Trade Development Co., Ltd

    Shanghai Yuexi Trade Development Co., Ltd

    Phone:(+86)189 1548 0537

    Phone

    (+86)189 1548 0537
    Economic power regulator PAC30A
    ◆ Adjustable power/voltage can be set
    ◆ Manual/automatic control
    ◆ Suitable for resistive loads
    ◆ Automatic+external voltage limit control
    ◆ Grounding/ungrounded load center can be set
    ◆ Special working voltage and frequency can be customized
    ◆ External switch controls start/stop
    ◆ CE certification
    Product Details
    Technical Specifications
    Product Model
    Product size

    Shanghai Yuexi Trade Development Co., Ltd. power regulator design concept

    1、Design of the Control Board

    PAC30A series: the use of digital circuit intelligent design, automatic phase discrimination, and strive for simple wiring and high quality requirements, low-cost design, basically achieve the cost of the solid state relay, while making up for the defects of the solid state relay, so that the function of PAC30A has reached: power regulation/voltage regulation arbitrary setting, initial power-on with slow start, manual/automatic adjustment output, output limit, load center grounding or non-grounding arbitrary setting, special voltage and frequency optional, etc.

    2、Selection of radiator

    The radiator adopts a blade radiator with high heat dissipation performance. 

    3、Selection of fans 

    120 axial fan, ball bearing type. It has the characteristics of long life and low heat generation.

    4. Selection of thyristor modules

     2 types of thyristor modules are used:

     A: The Ximenkang module imported from Germany is characterized by low heat generation and high reliability. 

     B: Domestic module, specially selected low-voltage drop chip, soldered and pressed with imported insulating materials with high heat dissipation performance Joined. It is characterized by strong overload capacity and reliable quality.

    1 Load Control Element
    hyristor (SCR) Module
    2 Load Power Supply
    Three-phase 380V AC ±10% 50HZ
    3 Current Capacity
    25A, 50A, 60A, 80A, 90A, 115A, 140A, 160A, 190A, 250A, 320A, 400A AC
    4 Control Board Power Supply and Power Consumption

    Power Supply: 380V AC ±10% 50HZ, requires same phase as load power supply 

    Power Consumption: 5W maximum

    5 Fan Power Supply (depending on model)
    Voltage: 220V AC  Current: Below 0.5 A
    6 Control Input
    4~20mA or 0-10V DC input, receiving impedance 100Ω
    7 LED Status Indicator  

    Input Indicator LED (1): Red 

    Three-color Status LED (1): Green, Running (output on) 

                       Yellow flashing, Stopped (no output) 

      Red-green flashing, Heat sink overtemperature alarm (no output)

    8 Control Mode

    Phase Control: Continuous voltage regulation        

    Power Control: Resistive cycle zero-crossing power regulation

    9 Output Resolution
    Phase Control: 0.2°, Power Control: 20ms
    10 Phase Shift Range

    0~175°, Star load (center point grounded) 

    0~150°, Delta load or Star load (center point ungrounded)

    11 Drive Output

    With single silicon anti-parallel thyristor module Variable width pulse: 8°~120°  

    Voltage: 5V   Current: 100mA maximum

    12 Manual Mode
    External 10KΩ potentiometer adjustment
    13 Soft Start Time
    During phase control, adjusted by P3 potentiometer. Adjustment range: 0.2~120 seconds
    14 Soft Shutdown Time
    During phase control, fixed at 10 seconds
    15 Voltage Limit

    Adjusted by onboard P1 potentiometer or external 10KΩ potentiometer.

    Adjustment range: 0~100%

    16 Heat Sink Overtemperature Protection
    80℃ temperature switch, normally closed contact Action time: < 20ms
    17 Alarm Output

    Activated when heat sink overtemperature 

    Specification: 1 normally open contact, 1A 250V AC resistive

    Output terminals: CN2-1, CN2-2

    18 Emergency Stop

    When the alarm is activated, the control output will stop urgently 

    Action time: < 20ms 

    Disable: After the alarm is dismissed, enter the standby state or power on again

    19 Fan Control

    The fan is connected to a normally open temperature switch at 40°C. When the heatsink temperature is below 40°C, the fan does not rotate, ensuring the fan's lifespan. 

    Fan power supply: 220V.

    20 Start/Stop Switch (External Switch)

    R1 terminal: CN1-3 terminal, RS terminal: CN1-7 terminal.

    R1 - RS terminal: Voltage-free contact input.

    Short-circuit voltage regulation (factory setting): slow shutdown, open circuit: slow start

    21

    Power regulation/voltage regulation switching

     (SW1-1 DIP Switch)

    SW1-1=ON, Voltage Regulation (Factory Setting)
    SW1-1=OFF, frequency power regulation
    22 Working environment
    and storage temperature
    Temperature range: 0~+40°C
    H
    umidity range: 90% RH max, no condensation
    Altitude: below 2000m
    Storage temperature: -10~+60°C
    Other requirements: good ventilation, no direct sunlight or thermal radiation, no corrosion sexual, flammable gases
    23 Installation form and requirements
    Wall-mounted, vertically mounted, well ventilated
    24 Insulation Insulationresistance
    Dielectric strength
    Insulation resistance: module output and housing, 500VDC 20MΩ minimum
    T
    he power supply end and enclosure of the control board are 500VDC 20MΩ minimum
    Control input and housing, 500VDC 20MΩ minimum
    The input and power supply of the control board are 500VDC 20MΩ minimum
    Dielectric Strength: 2000VAC for 1 minute between module output and housing
    Between the control power supply and the housing, 2000VAC for 1 minute


    Classic (SCR) Three-Phase Power Regulator Selection Table


    Code  
    Basic parameters
    PAC30A-

    Input signal: 4-20mA DC signal (input impedance 120 ohms), output form phase shift voltage regulation/frequency power regulation can be set arbitrarily, power on slow start 0-60 seconds can be set, radiator over-temperature alarm protection, manual automatic non-disturbance switching. It is suitable for Y-type load center connection or dangling, triangular load. Load power supply 380VAC ± 10%, 50Hz

    The default input signal is 4-20 mA, and the 0-5V and 0-10V input require remarks The default power supply of the fan is 380V pass-through, and 220V control is required.

    Radiator unit
    Overall dimensions of the whole machine
    SCR specifications
    Load power (resistive)
    B125C-: 1 fan, blow-type forced air cooling. Radiator capacity: ambient temperature at 40 degrees: 60A/phase. Natural heat dissipation conditions: 10A/phase.
    L 270 x W 127 x D 212mm 2 Hole Mounting,
    Upper and lower mounting hole spacing:253mm, hole diameter 10mm
    MKKT55A
    26KW
    MKKT90A
    40KW
    MKKT110A
    40KW
    B170C-: 1 fan, blow-type forced air cooling. Radiator capacity: ambient temperature at 40 degrees: 150A/phase. Natural heat dissipation conditions: 15A/phase.
    L 290 x W 172 x D 253mm 4 Hole Mounting,

    Mounting hole spacing:148*273mm, 

    hole diameter 10mm

    MKKT110A
    50KW
    MKKT130A
    62KW
    MKKT160A
    80KW
    MKKT180A
    90KW
    MKKT200A
    98KW
    B210C-: 2 fans, blow-type forced air cooling. Radiator capacity: ambient temperature at 40 degrees: 220A/phase. Natural heat dissipation conditions: 70A/phase
    L 285 x W250 x D 255mm 4 Hole Mounting,

    Mounting hole spacing:222*268mm,

    hole diameter 10mm

    MKKT180A
    100KW
    MKKT200A
    115KW
    B240C-: 2 fans, blow-type forced air cooling, Radiator capacity: at ambient temperature 40 degrees: 200A/phase, Natural heat dissipation: 70A/phase.
    L 285 x W 250 x D255mm 4 Hole Mounting,
    Mounting hole spacing:222*268mm, hole diameter 10mm
    MKKT250A
    115KW
    B300C-: 2 fans, blow-type forced air cooling, Radiator capacity: 300A/phase at ambient temperature 40 degrees, Natural heat dissipation: 100A/phase.
    L 360 x W 246 x D 243mm 4 Hole Mounting,
    Mounting hole spacing:222*343mm, hole diameter 10mm
    MKKT300A
    115KW
    B350C-: 2 fans, blow-type forced air cooling, Radiator capacity: ambient temperature at 40 degrees: 350A/phase. Natural heat dissipation conditions: 100A/phase.
    L 460 x W 244 x D 283mm 4 Hole Mounting,

    Mounting hole spacing:220*443mm,

     hole diameter 10mm

    MKKT500A
    210KW
    B400C-: 2 fans, blow-type forced air cooling. Radiator capacity: ambient temperature at 40 degrees: 630A/phase. Natural heat dissipation conditions: 100A/phase.
    L 477 x W 365 x D 330mm 4 Hole Mounting,

    Mounting hole distance:341*457mm,

     hole diameter 10mm

    MKKT600A
    265KW
    SKKT570A
    400KW

    unit mm A B C D E
    B30C 210 127 212 102 198
    B125C 270 127 220 102 247
    B170C 290 172 253 148 273
    B210C 285 250 255 222 268
    B240C 285 250 255 222 268
    B300C 360 246 243 222 343
    B350C 460 244 283 220 443
    B400C 477 304 295 280 455
    B600C 473 365 330 341 457