    PAC30A-B160S series new three-phase power regulator
    ◆ Adjustable power/voltage can be set
    ◆ Manual/automatic control
    ◆ Suitable for resistive loads
    ◆ Automatic+external voltage limit control
    ◆ Grounding/ungrounded load center can be set
    ◆ Special working voltage and frequency can be customized
    ◆ External switch controls start/stop
    ◆ CE certification
    Product Details
    Technical Specifications
    Product Model
    Product size


    Shanghai Yuexi Trade Development Co., Ltd. power regulator design concept

    1、Design of the Control Board

    PAC30A series: the use of digital circuit intelligent design, automatic phase discrimination, and strive for simple wiring and high quality requirements, low-cost design, basically achieve the cost of the solid state relay, while making up for the defects of the solid state relay, so that the function of PAC30A has reached: power regulation/voltage regulation arbitrary setting, initial power-on with slow start, manual/automatic adjustment output, output limit, load center grounding or non-grounding arbitrary setting, special voltage and frequency optional, etc.

    2、Selection of radiator

    The radiator adopts a blade radiator with high heat dissipation performance. 

    3、Selection of fans 

    120 axial fan, ball bearing type. It has the characteristics of long life and low heat generation.

    4. Selection of thyristor modules

     2 types of thyristor modules are used:

     A: The Ximenkang module imported from Germany is characterized by low heat generation and high reliability. 

     B: Domestic module, specially selected low-voltage drop chip, soldered and pressed with imported insulating materials with high heat dissipation performance Joined. It is characterized by strong overload capacity and reliable quality.



    1 Load Control Element
    hyristor (SCR) Module
    2 Load Power Supply
    Three-phase 380V AC ±10% 50HZ
    3 Current Capacity
    25A, 50A, 60A, 80A, 90A, 115A, 140A, 160A, 190A, 250A, 320A, 400A AC
    4 Control Board Power Supply and Power Consumption

    Power Supply: 380V AC ±10% 50HZ, requires same phase as load power supply

    Power Consumption: 5W maximum

    5

    Fan Power Supply

    (depending on model)

    Voltage: 220V AC  Current: Below 0.5 A
    6 Control Input
    4~20mA or 0-10V DC input, receiving impedance 100Ω
    7 LED Status Indicator  

    Input Indicator LED (1): Red 

    Three-color Status LED (1): Green, Running (output on) 

                       Yellow flashing, Stopped (no output) 

      Red-green flashing, Heat sink overtemperature alarm (no output)

    8 Control Mode

    Phase Control: Continuous voltage regulation        

    Power Control: Resistive cycle zero-crossing power regulation

    9 Output Resolution
    Phase Control: 0.2°, Power Control: 20ms
    10 Phase Shift Range

    0~175°, Star load (center point grounded) 

    0~150°, Delta load or Star load (center point ungrounded)

    11 Drive Output

    With single silicon anti-parallel thyristor module Variable width pulse: 8°~120°  

    Voltage: 5V   Current: 100mA maximum

    12 Manual Mode
    External 10KΩ potentiometer adjustment
    13 Soft Start Time
    During phase control, adjusted by P3 potentiometer. Adjustment range: 0.2~120 seconds
    14 Soft Shutdown Time
    During phase control, fixed at 10 seconds
    15 Voltage Limit

    Adjusted by onboard P1 potentiometer or external 10KΩ potentiometer.

    Adjustment range: 0~100%

    16 Heat Sink Overtemperature Protection
    80℃ temperature switch, normally closed contact Action time: < 20ms
    17 Alarm Output

    Activated when heat sink overtemperature 

    Specification: 1 normally open contact, 1A 250V AC resistive

    Output terminals: CN2-1, CN2-2

    18 Emergency Stop

    When the alarm is activated, the control output will stop urgently 

    Action time: < 20ms 

    Disable: After the alarm is dismissed, enter the standby state or power on again

    19 Fan Control

    The fan is connected to a normally open temperature switch at 40°C. When the

    heatsink temperature is below 40°C, the fan does not rotate, ensuring the fan's lifespan. 

    Fan power supply: 220V.

    20 Start/Stop Switch (External Switch)

    R1 terminal: CN1-3 terminal, RS terminal: CN1-7 terminal.

    R1 - RS terminal: Voltage-free contact input.

    Short-circuit voltage regulation (factory setting): slow shutdown, open circuit: slow start

    21

    Power regulation/voltage regulation switching

     (SW1-1 DIP Switch)

    SW1-1=ON, Voltage Regulation (Factory Setting)
    SW1-1=OFF, frequency power regulation
    22 Working environment
    and storage temperature
    Temperature range: 0~+40°C
    H
    umidity range: 90% Rmax, ncondensation
    Altitude: below 2000m
    Storage temperature: -10~+60°C

    Other requirements: good ventilation, ndirect sunlight othermal radiation, no

    corrosion sexual, flammable gases

    23 Installation form and requirements
    Wall-mounted, vertically mounted, well ventilated
    24 Insulation Insulationresistance
    Dielectric strength
    Insulation resistance: module output and housing, 500VDC 20MΩ minimum

    The power supply end and enclosure of the control board are 500VDC 20MΩ minimum
    Control input and housing, 500VDC 20MΩ minimum
    The input and power supply othe control board are 500VDC 20MΩ minimum
    Dielectric Strength: 2000VAC for 1 minute between module output and housing

    Between the control power supply and the housing, 2000VAC for 1 minute


    Classic SCR three-phase power regulator selection table


    Code  
    Basic parameters
        PAC30A-     

    Input signal: 4-20mA DC signal (input impedance 120 ohms), output form phase shift voltage regulation/frequencyower regulation can be set arbitrarily,power on slow start 0-60 seconds 

    can be set, radiator over-temperature alarm protection, manual automatic non-disturbance switching. It is suitable for Y-type load center connection or dangling, triangular load. Load power supply 380VAC ± 10%, 50Hz

    The default input signal is 4-20 mA, and the 0-5V and 0-10V input require remarks The default power supply of the fan is 380V pass-through, and 220V control is required.

        Radiator unit   
    Overall dimensions of the whole machine
    SCR specifications

    Load power

     (resistive)

    B160S-: 1 fan, blow-type forced air cooling. Radiator capacity: ambient temperature at 40 degrees: 150A/phase. Natural heat dissipation conditions: 15A/phase.
    L 290mm, W 170mm, D 240mm, 4 hole mounting
    Mounting hole spacing:100mm*274mm, 
    hole diameter 10mm
    MKKT90A
    42KW
    MKKT110A
    52KW
    MKKT130A
    63KW
    MKKT180A
    90KW
    MKKT200A
    98KW

    unit mm A B C D E
    B160S 290 171 240 100 274