  • Temperature Control System Solution Provider - Shanghai Yuexi Trade Development Co., Ltd

    Shanghai Yuexi Trade Development Co., Ltd

    Phone:(+86)189 1548 0537

    Phone

    (+86)189 1548 0537
    PAC60A series new three-phase power regulator
    ◆ Adjustable power/voltage can be set
    ◆ Manual/automatic control
    ◆ Constant current, current limiting, overcurrent alarm
    ◆ Automatic+external voltage limit control
    ◆ Grounding/ungrounded load center can be set
    ◆ Suitable for inductive loads such as transformers
    ◆ Special working voltage and frequency can be customized
    ◆ External switch controls start/stop
    ◆ CE certification
    Product Details
    Technical Specifications
    Product Model
    Product size

    Shanghai Yuexi Trade Development Co., Ltd. power regulator design concept


    1、Design of the Control Board

    PAC60A series: the use of digital circuit intelligent design, automatic phase discrimination, and strive for simple wiring high quality requirements, low-cost design, its function on the basis of PAC30A increases: current feedback, so that it has: constant current, overcurrent and other functions, control transformer primary side and other inductive load is better.


    2、Selection of radiator

    The radiator adopts a blade radiator with high heat dissipation performance. 

    3、Selection of fans 

    120 axial fan, ball bearing type. It has the characteristics of long life and low heat generation.

    4. Selection of thyristor modules


    Domestic module, specially selected low-voltage drop chip, soldered and pressed with imported insulating materials with high heat dissipation performance Joined. It is characterized by strong overload capacity and reliable quality.

    1 Load Control Element
    Hyristor (SCR) Module
    2 Load Power Supply
    Three-phase 380V AC ±10% 50HZ
    3 Current Capacity
    25A, 50A, 60A, 80A, 90A, 115A, 140A, 160A, 190A, 250A, 320A, 400A AC
    4

    Control Board Power Suppl

    and Power Consumption

    Power Supply: 380V AC ±10% 50HZ, requires same phase as load power supply 

    Power Consumption: 5W maximum

    5

    Fan Power Supply

    (depending on model)

    Wiring required: 5 and 6 terminals of a six-wire terminal strip

    Voltage: 220V AC 50/60Hz,20W/pcs.

    Current: Below 0.5 A 

    6 Control Input
    4~20mA or 0-10V DC input, receiving impedance 100Ω
    7 LED Status Indicator

    Input Indicator LED (1): Red 

    Three-color Status LED (1): Green, Running (output on) 

                       Yellow flashing, Stopped (no output)

                         Red, overcurrent 

      Red-green flashing, Heat sink overtemperature alarm (no output)


    8 Control Mode

    Phase Control: Continuous voltage regulation

    Power Control: Resistive cycle zero-crossing power regulation

    PWM zero-crossing power regulation

    9 Output Resolution
    Phase Control: 0.2°, Power Control: 20ms
    10 Phase Shift Range

    0~175°, Star load (center point grounded) 

    0~150°, Delta load or Star load (center point ungrounded)

    11 Drive Output

    With single silicon anti-parallel thyristor module Variable width pulse: 8°~120°  

    Voltage: 5V   Current: 100mA maximum

    12 Manual Mode
    External 10KΩ potentiometer adjustment
    13 Soft Start Time
    During phase control, adjusted by P3 potentiometer. Adjustment range: 0.2~120 seconds
    14 Soft Shutdown Time 
    During phase control, fixed at 10 seconds
    15 Voltage Limit

    Adjusted by onboard P1 potentiometer or external 10KΩ potentiometer.

    Adjustment range: 0~100%

    16 Heat Sink Overtemperature Protection
    80℃ temperature switch, normally closed contact Action time: < 20ms
    17 Alarm Output

    When the radiator is over-temperature and the current is overcurrent, it operates

    Specification: 1 normally open contact, 1A 250V AC resistive
    Output terminals: CN2-1, CN2-2

    18 Emergency Stop

    When the alarm is activated, the control output will stop urgently 

    Action time: < 20ms 

    Disable: After the alarm is dismissed, enter the standby state or power on again

    19 Fan Control

    The fan is connected to a normally open temperature switch at 40°C. When the heatsink temperature is below 40°C, the fan does not rotate, ensuring the fan's lifespan. 
    Fan power supply: 220V.

    20

    Start/Stop Switch

    (External Switch)

    R1 terminal: CN1-3 terminal, RS terminal: CN1-8 terminal.
    R1 - RS terminal: Voltage-free contact input.
    Short-circuit voltage regulation (factory setting): slow shutdown, open circuit: slow start

    21

    ower regulation/voltage regulation/constant 

    current switching

    (SW1 DIP Switch)

    When SW1-1=ON and SW1-2=ON, voltage regulation + current limiting.
    When SW1-1=ON and SW1-2=OFF, constant current + current limiting.
    When SW1-1=OFF and SW1-2=ON, cycle power regulation + current limiting.
    When SW1-1=OFF and SW1-2=OFF, PWM power regulation (no current limiting function).
    22

    Constant current control

     + current limiting

    Current Limiting: Adjusted by the onboard P4 potentiometer or an external current-limiting potentiometer.
    Adjustment Range: 20% to 100%. To cancel current limiting: Turn the P4 potentiometer to maximum or remove the external current-limiting potentiometer.
    Constant Current Control: SW1-1 = ON, SW1-2 = OFF
    During constant current control, it is not possible to test with a dummy load (because the load current is too small).
    In this case, only open-loop testing is possible (SW1-1 = ON, SW1-2 = ON).

    23 Overcurrent alarm
    Adjusted by the onboard P2 potentiometer.
    Adjustment range: 100% to 150%.
    Overcurrent setting: Adjusted by the onboard P2 potentiometer.
    Overcurrent alarm: Alarm activates during overcurrent, and the tricolor light turns red.
    Response time: < 20ms.
    24 Working environment
    and storage temperature
    Temperature range: 0~+40°C
    Humidity range: 90% RH max, no condensation
    Altitude: below 2000m
    Storage temperature: -10~+60°C
    Other requirements: good ventilation, no direct sunlight or thermal radiation, no corrosion sexual, flammable gases
    25 Insulation Insulationresistance
    Dielectric strength

    Insulation Resistance:
    Between module output terminals and casing: 500VDC, minimum 20MΩ
    Between control board power terminals and casing: 500VDC, minimum 20MΩ
    Between control input terminals and casing: 500VDC, minimum 20MΩ
    Between control board input terminals and power terminals: 500VDC, minimum 20MΩ
    Dielectric Strength:
    Between module output terminals and casing: 2000VAC, 1 minute
    Between control power terminals and casing: 2000VAC, 1 minute



    PAC60A Three-Phase Power Controller Selection Guide


      PAC60A-  

    Input Signal: 4-20mA (input impedance 100Ω), Output Mode: Voltage regulation or cycle power regulation.

    Features include soft start and shutdown upon power-up, overheating alarm for the heat sink, and seamless manual-automatic switching. Suitable for star-grounded, ungrounded, or delta-connected inductive and resistive loads, equipped with current limiting and overcurrent protection. Effectively controls silicon carbide rods, silicon molybdenum rods, heating tubes, nichrome wires, transformers, etc.

    If 0-10VDC or 0-5VDC input is required, please specify when ordering.
     Radiator unit
    Overall dimensions of the whole machine
    SCR specifications

    Load power

     (resistive)

    B125C-: 1 fan, blow-type forced air cooling. Radiator capacity: ambient temperature at 40 degrees: 60A/phase. Natural heat dissipation conditions: 10A/phase.
    L 270 x W 127 x D 212mm 2 Hole Mounting,

    Upper and lower mounting hole spacing:253mm, 

    hole diameter 8mm

    MKKT55A
    ≤29KW
    MKKT70A
    ≤35KW
    MKKT90A
    ≤44KW
    MKKT110A
    ≤44KW
    B170C-: 1 fan, blow-type forced air cooling. Radiator capacity: ambient temperature at 40 degrees: 150A/phase. Natural heat dissipation conditions: 15A/phase.
    L 290 x W 172 x D 253mm 4 Hole Mounting,
    Mounting hole spacing:148*273mm, 
    hole diameter 8mm
    MKKT90A
    ≤44KW
    MKKT110A
    ≤54KW
    MKKT160A
    ≤90KW
    MKKT180A
    ≤92KW
    B210C-: 2 fans, blow-type forced air cooling. Radiator capacity: ambient temperature at 40 degrees: 220A/phase. Natural heat dissipation conditions: 70A/phase
    L 285 x W250 x D 255mm 4 Hole Mounting,
    Mounting hole spacing:222*268mm,
    hole diameter 8mm
    MKKT160A
    ≤92KW
    MKKT180A
    ≤98KW
    MKKT200A
    ≤105KW
    B240C-: 2 fans, blow-type forced air cooling, Radiator capacity: at ambient temperature 40 degrees: 200A/phase, Natural heat dissipation: 70A/phase.
    L 285 x W 250 x D255mm 4 Hole Mounting,

    Mounting hole spacing:222*268mm,

     hole diameter 8mm

    MKKT250A
    ≤115KW
    B300C-: 2 fans, blow-type forced air cooling, Radiator capacity: 300A/phase at ambient temperature 40 degrees, Natural heat dissipation: 100A/phase.
    L 360 x W 246 x D 243mm 4 Hole Mounting,

    Mounting hole spacing:222*343mm, 

    hole diameter 8mm

    MKKT300A
    ≤157KW
    B350C-: 2 fans, blow-type forced air cooling, Radiator capacity: ambient temperature at 40 degrees: 350A/phase. Natural heat dissipation conditions: 100A/phase.
    L 460 x W 244 x D 283mm 4 Hole Mounting,
    Mounting hole spacing:220*443mm,
     hole diameter 8mm
    MKKT500A
    ≤210KW
    B400C-: 2 fans, blow-type forced air cooling. Radiator capacity: ambient temperature at 40 degrees: 630A/phase. Natural heat dissipation conditions: 100A/phase.
    L 477 x W 365 x D 330mm 4 Hole Mounting,
    Mounting hole distance:341*457mm,
     hole diameter 10mm
    MKKT600A
    ≤265KW
    B600C-: 2 fans, blow-type forced air cooling. Radiator capacity: ambient temperature at 40 degrees: 1000A/phase. Natural heat dissipation conditions: 200A/phase.
    L 473 x W 365 x D 330mm 4 Hole Mounting,
    Mounting hole distance:341*457mm,
     hole diameter 10mm
    SKKT570A
    ≤400KW

    unitmm A B C D E
    B30C 210 127 212 102 198
    B125C 270 127 220 102 247
    B170C 290 172 253 148 273
    B210C 285 250 255 222 268
    B240C 285 250 255 222 268
    B300C 360 246 243 222 343
    B350C 460 244 283 220 443
    B400C 477 304 295 280 455
    B600C 473 365 330 341 457
     